R-Value Calculator
Add up the R-values of the layers of a wall or ceiling, and get its U-factor.
U-factor 0.05 BTU/h·ft²·°F, through the insulation
- Insulation only
- R-17.6
- U-factor (1 ÷ R, BTU/h·ft²·°F)
- 0.0497
- Metric RSI (m²·K/W)
- RSI 3.54
How it works
Total R = sum of the R-values of every layer · U = 1 ÷ R · insulation R = R per inch × inches
Example: Cavity insulation batt · Insulation thickness 5.5 in · Continuous rigid foam none · Sheathing osb · Siding vinylSiding · 1/2 in drywall inside (R-0.45) true · Include air films (R-0.85) true → R-20.1 (insulation only: R-17.6, u-factor (1 ÷ r, btu/h·ft²·°f): 0.0497, metric rsi (m²·k/w): RSI 3.54).
R-value measures resistance to heat flow; layers in series simply add up. A 2×6 wall with 5.5 in of fiberglass batts (5.5 × 3.2 = R-17.6), 7/16 in OSB (0.62), vinyl siding (0.61), 1/2 in drywall (0.45) and the inside and outside air films (0.68 + 0.17) totals about R-20.1 through the insulation, a U-factor of 0.050.
One inch of polyiso foam outside the sheathing adds R-6 everywhere, including over the studs, which lose heat faster than the insulated cavities. Codes rate insulation by the R printed on it, without air films or other materials.
This is the R-value through the insulated part. Wood framing, about 15–25% of a wall, has only about R-1.1 per inch, so the whole-wall R-value is lower. Use the U-factor (1 ÷ R) to estimate heat loss: heat flow = U × area × temperature difference.
Questions
What is the R-value of a 2x6 wall?
About R-20 through the cavity with R-19 batts compressed to 5.5 in, sheathing, siding and drywall.
How do I calculate total R-value?
Add the R-values of every layer; R-values in series add up.
What is the difference between R-value and U-factor?
U-factor is 1 ÷ R: the lower the U, the better the insulation.